| It is widely used for semiautomatic defrost single-door refrigerator Specfication: 1)designed temperature range:-28~7 2)on-off temperature difference:6-14 3)adjustable temperature range:max18 4)rated at 6A/250V 50/60HZ 5)defrost temperature:3~6 6)the center of installing hole:55±0.25mm or 15.3+0.5mm 7)operating life:no less than200,000times 8)manufactured on customer request |
| Type | Action Temperature (℃ ) | Thaw frost Temp | Max Temp of Sensor (℃ ) | Capillary tube (mm) | Puffing type | ||||||
| Forced OFF | Warm Point | Normal Point | Cold Point | ||||||||
| ON | OFF | ON | OFF | ON | OFF | ||||||
| WSF23A-L | Yes | -1.5 ± 1.5 | -9 ± 1.5 | --- | --- | --- | -22 ± 2 | 6 ± 2 | 80 | 650 | GAS |
| WSF19.5A-L | Yes | (7) | 1.5 ± 2.5 | -3.5 ± 1.5 | -11 ± 1.5 | (-10) | -19.5 ± 2.5 | 5 ± 2.5 | 80 | 600 | GAS |
| WSF18A-L | Yes | 3 ± 2 | (-10) | -1 ± 1.5 | -14 ± 1.5 | (-4) | -18 ± 2 | 5 ± 2.5 | 80 | 733 | GAS |
| WSF20A-L | Yes | (4) | --- | 0 ± 1.5 | -8.5 ± 1.5 | --- | -20 ± 2 | 5 ± 2.5 | 80 | 700 | GAS |