| It is widely used for freezer Specfication: 1)designed temperature range:-36~15 2)on-off temperature difference:5~14 3)adjustable temperature range:max16 4)signal temperature difference:0~6 5)the center of installing hole:55±0.25mm or 15.3+0.5mm 6)operating life:no less than 200,000times 7)manufactured on customer request |
| Type | Action Temperature (℃ ) | Temp (℃ ) | Max Temp of Sensor (℃ ) | Capillary tube (mm) | Puffing type | ||||||
| Forced OFF | W | N | C | ||||||||
| ON | OFF | ON | OFF | ON | OFF | ||||||
| WPF32A-LX | --- | -11 ± 2 | -18 ± 2 | -17 ± 1.5 | -25 ± 1.5 | -22±2 | - 32 ± 2 | w:-7.5 ± 2 | 80 | 815 | GAS |
| WPF32.5A-LX | Yes | -16 ± 1.5 | -24.5 ± 1.5 | --- | --- | (-22) | - 32.5 ± 2 | w:-11 ± 2 | 80 | 600 | GAS |
| WPF31A-LX | Yes | -14.5 ± 1.5 | - 23 ± 1.5 | --- | --- | (-20.6) | (- 31 ± 2) | w:-11 ± 2 | 80 | 600 | GAS |
| WPF33.5B-LX | Yes | -15 ± 1.5 | -25 ± 1.5 | --- | --- | --- | -33.5 ± 2 | w:-12 ± 2 | 80 | 600 | GAS |