WDFE series


详细内容

It is widely used for refrigerator&freezer(R600 refrigerant)
Specfication:
1)designed temperature range:3~8
2)stop temperature range: -30~ -6
3)adjustable temperature rnage:Max19
4)the center of installing hole:55±0.25mm or 15.3+0.5mm
5)operating life:no less than 200,000times
6)manufacture on customer request
Type Action Temperature (℃ ) Max Temp of Sensor
(℃ ) 
Capillary tube (mm) Puffing type
Forced 
OFF
Warm Point Normal Point Cold Point Forced 
ON
ON OFF ON OFF ON OFF
WDFE31C-L Yes 3 ± 1.5 -16 ± 2 --- --- 3 ± 1.5 -31 ± 2 Yes 80 650 GAS
WDFE24D-L Yes 4 ± 1.1 -11 ± 2 4 ± 1.1 -17 ± 1.5 4 ± 1.1 -24 ± 2 Yes 80 633 GAS